Axis of control: 1.
Interpolation: No.
Program memory: built-in 3.8k step EEPROM.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Not only can deal with single speed positioning and positioning,
Can also carry on the multi section fast operation and so on complex control MITSUBISHI FX1S-20MT-DSS HARDWARE MANUAL.
Can not be connected to the PLC, while running alone
FX1S-20MT-DSS
1 can control 1 axes,
FX1N, FX2N, PLC FX3U up to 8 units can be connected,
PLC FX2NC up to 4 units can be connected,
FX3UC PLC can connect up to 7 units, and a plurality of shafts can be independently controlled.
Can output up to 200kHz of the pulse train.
The connection function of the absolute position detection function and the manual pulse generator MITSUBISHI FX1S-20MT-DSS HARDWARE MANUAL.
Can be used in the form of flow chart programming software, visual programming. "MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification MITSUBISHI FX1S-20MT-DSS HARDWARE MANUAL.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter. "Application: input power line for extended input module.
Length: 1.0m.
Auxiliary parts for FX3GC and FX3UC. Max input / output points: 60 points.
Supply voltage: 100 - 240VAC.
Input points: 36 points.
Output points: 24 points.
Output type: relay.
Power consumption (W): 35.
Weight (kg):0.8.
Size (WxHxD) mm:175x90x75.
Rich functionality.
FX series of products are rich in variety, users can be based on cost or application,
Choose the most suitable product. Will find a suitable model for the user site.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc FX1S-20MT-DSS Manual. .
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed.
In addition, you can also reduce the input output oor special module FX1S-20MT-DSS Manual.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards.