MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 400kw.
SLD converter rated current: 866A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON MITSUBISHI FX3G-24MT/DS HARDWARE MANUAL
FX3G-24MT/DS
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation MITSUBISHI FX3G-24MT/DS HARDWARE MANUAL.
Can reduce the power consumption in the stop. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 45kw.
SLD converter rated current: 93A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup MITSUBISHI FX3G-24MT/DS HARDWARE MANUAL.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 132kw.
SLD converter rated current: 361A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of tthe inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements FX3G-24MT/DS Manual.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out FX3G-24MT/DS Manual.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "