Connecting cable for handheld GOT and PLC.
Cable length: 3 meters.
Application: RS-422 connection. Power: 30kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function MITSUBISHI FX3U-4AD-ADP User's Manual. Input and output points: 14 points
FX3U-4AD-ADP
Power supply: DC24V.
Input points: 8 points.
Output points: 6 points.
Output form: transistor output (source).
Power consumption: 6.5W.
Weight: 0.22KG.
Outline dimension: 60x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features.
Special adaptor and function expansion board can be installed and used FX3 series MITSUBISHI FX3U-4AD-ADP User's Manual.
High speed operation.
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models MITSUBISHI FX3U-4AD-ADP User's Manual.
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on. Function: bus convert FX5 to FX3.
Input and output points: 8 points.
Conversion module connecting FX3 series expansion module.
FX3 series expansion module, only the right side of the bus conversion module can be connected. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 90kw.
SLD converter rated current: 260A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of tthe inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements FX3U-4AD-ADP Manual.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out FX3U-4AD-ADP Manual.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "