Function: input / output module (internal service power supply).
Input / output points: 32 points
Input points: 16 points.
Output points: 16 points.
DC5V internal consumption current: 965mA.
DC24V internal consumption current: 250mA.
Input / output mode: DC input (drain / source) / relay output.
In order to extend the input output of the device MITSUBISHI FX3U-64DP-M INSTALLATION MANUAL.
Also has a built-in power supply products
FX3U-64DP-M
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Series Name: hand held F940GOT.
System screen display language: english.
Display: 5 MITSUBISHI FX3U-64DP-M INSTALLATION MANUAL. 7 inches, can operate in the palm of the GOT.
Display color: monochrome.
Display device: LCD STN.
Resolution: 320 * 240.
Installation type: panel mounting.
The built-in communication port: RS-422 (1ch).
Power supply voltage: DC24V.
GOT-F900 series can be easily applied to a variety of different applications.
3 built-in communication channels.
Screen area.
Through the split screen configuration, you can reduce the operating time MITSUBISHI FX3U-64DP-M INSTALLATION MANUAL.
The image can be divided into two or three parts to display.
According to the user''s application example, the menu screen or the operation of the button sometimes on the screen will often be used to.
As a result, it is very time-consuming and inefficient to make a similar picture every time. Output points: 32 points
Output form: Transistor (drain type).
Connection status: connector.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Axis of control: 2.
Interpolation: there are.
Program memory: built-in 7.8k step RAM.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Can control 2 axes for linear interpolation, arc interpolation.
Can not be connected to the PLC, while running alone.
1 can control 1 axes,
FX1N, FX2N, PLC FX3U up to 8 units can be connected,
PLC FX2NC up to 4 units can be connected,
FX3UC PLC can connect up to 7 units, and a plurality of shafts can be independently controlled FX3U-64DP-M Manual.
Can output up to 200kHz of the pulse train.
The connection function of thhe absolute position detection function and the manual pulse generator FX3U-64DP-M Manual.
Can be used in the form of flow chart programming software, visual programming.