Product model: GX-EC0211
Name: TEMPERATURE INPUT UNIT
Brand: OMRON
Sort: Safety Precautions
File language: English
File size: 0.78MB
Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators OMRON TEMPERATURE INPUT UNIT Safety Precautions.
Phase control or optimum cycle control GX-EC0211
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance OMRON TEMPERATURE INPUT UNIT Safety Precautions.
UL, and IEC/EN (TÜV) certified. Action indicator: there are.
Applicable load of output: AC100 5A ~ 240V.
Input rated voltage: DC5 ~ 24V.
Insulation: photo coupler.
Zero crossing trigger function.
Socket terminal type with same shape as MK type power relay.
New international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification OMRON TEMPERATURE INPUT UNIT Safety Precautions. (type -VD)
Socket terminal type of same size with MK (2 pole type).
A model with an action indicator to check the status of the input. Isolation: Photocoupler.
Zero cross function: Yes GX-EC0211 Safety Precautions.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 90 A at 200 to 480 VAC(See note 2.).
Rated input voltage: 5 to 24 VDC GX-EC0211 Safety Precautions.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges GX-EC0211 Safety Precautions.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). I/O classification: Temperature inputs.
I/O points: 4 inputs.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
Input specification: Platinum resistance thermometer.
Temperaature Input Units for use with MULTIPLE I/O TERMINAL GX-EC0211 Manual.
Four inputs.
Thermocouples and platinum resistance thermometer models,
are available.
Conversion time is only 250 ms for 4 inputs.
The Configuurator can be used to calibrate temperatures OMRON TEMPERATURE INPUT UNIT Safety Precautions.
The circuit section can be removed, so rewiring isn’t,
required during maintenance.
DIN track mounting.
Related products
OMRON
Analog I/O Terminal 2-tier Terminal Block Type
GX-EC0241
OMRON Analog I/O Terminal 2-tier Terminal Block Type GX-EC0241
EtherCAT-compatile encoder input terminal wh
OMRON
Analog I/O Terminal 2-tier Terminal Block Type
GX-EC0211
OMRON Analog I/O Terminal 2-tier Terminal Block Type GX-EC0211
EtherCAT-compatile encoder input terminal wh