Product model: A1SX81-S2
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 5.14MB
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0 A1SX81-S2 Manual. 5A.
External connection: 3 line /2 line type.
Spring clip terminal A1SX81-S2
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting A1SX81-S2 Manual.
Can be used for the 3 wire sensor input wiring. Series Name: A953GOT.
Size: 6 inches.
Resolution: 320 * 240.
Display equipment: high brightness TFT color display.
Display color: 256 color.
Power supply: DC24V.
The built-in RS-232 communication interface.
Memory card: 3M.
Design any machine interface, generally have to consider the system response time, user assistance mechanism, error information processing and command mode four aspects A1SX81-S2 Manual.
System response time is too long to be the most users in the interactive system,
In addition to the absolute length of the response time, the user is also very concerned about the difference in response to different commands in response time,
If too wide users will be difficult to accept; user assistance mechanism should be integrated,
Avoid overlay systems that cause users to turn to a guide and have to browse a large number of irrelevant information;
Error and warning information must be selected in terms of user''s clarity and meaning,
At the same time, it should be as far as possible to provide some suggestions on the recovery of errors MITSUBISHI A1SX81-S2 User's Manual MITSUBISHI A1SX81-S2 User's Manual MITSUBISHI A1SX81-S2 User's Manual.
In addition, when the error message is displayed, the effect is better if it is supplemented by the auditory (Bell) and visual (special color) stimulus;
Command mode is the best menu and keyboard commands, for the user to choose. For A6TBXE/A6TBY36E/A6TBX54E/A6TBY54E/A6TBX70E (common cathode; source) long 2m.Output points: 8 points.
Output voltage and current: 0.3A/1, DC12/24V point.
Response time: 2ms.
All points of independence.
Output form: transistor output, leakage type.
26 point terminal station.
Number of stations: 1 stops.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Etherrnet module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system A1SX81-S2 .
At the same time, tthe use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information A1SX81-S2 Manual.
Related products
MITSUBISHI
DC source type input module
A1SX80-S2
MITSUBISHI DC source type input module A1SX80-S2
Type of input: DC source. Input points: 16 po
MITSUBISHI
DC leakage type input module
A1SX41
MITSUBISHI DC leakage type input module A1SX41
Type of input: DC leakage. Input points: 32 p
MITSUBISHI
Type DC input module
QX81-S2
MITSUBISHI Type DC input module QX81-S2
Input points: 32 points. Input voltage and cu
MITSUBISHI
Input / output module
A1SX48Y58
MITSUBISHI Input / output module A1SX48Y58
Type of input: DC leakage. Input points: 8 po