LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> INVERTER FR-A720-00030 to 03460-NA INSTRUCTION MANUAL MITSUBISHI FR-A720-00030 to 03460-NA Manual

INVERTER FR-A720-00030 to 03460-NA INSTRUCTION MANUAL MITSUBISHI FR-A720-00030 to 03460-NA Manual

Product model: FR-A720-00030 to 03460-NA
Name: INVERTER
Brand: MITSUBISHI
Sort: INSTRUCTION MANUAL
File language: English
File size: 17.81MB
MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 45KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment FR-A720-00030 to 03460-NA INSTRUCTION MANUAL.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit FR-A720-00030 to 03460-NA
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on FR-A720-00030 to 03460-NA INSTRUCTION MANUAL. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 1.5kw.
SLD converter rated current: 3.8A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed FR-A720-00030 to 03460-NA INSTRUCTION MANUAL.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor MITSUBISHI FR-A720-00030 to 03460-NA Manual.
Load torque is smaller, can further improve energy efficiency MITSUBISHI FR-A720-00030 to 03460-NA Manual.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output MITSUBISHI FR-A720-00030 to 03460-NA Manual. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 560KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testinng equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A720-00030 to 03460-NA .
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A720-00030 to 03460-NA INSTRUCTION MANUAL. "
Related products