Max input / output points: 40 points.
Power supply voltage: DC24V.
Input points: 24 points.
Output points: 16 points.
Output type: transistor.
Power consumption (W): 32.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x75.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board FR-A840-00930-2-60 Manual .
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect
FR-A840-00930-2-60
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control FR-A840-00930-2-60 Manual . Station type: Master station.
Maximum number of stations: maximum 16.
Occupied points: 8 points.
Transfer speed: 10Mbps.
Power supply: 240mA DC24V.
Weight: 0.3kg.
FX3U-16CCL-M is the master module of V2 CC-LINK.
The main station can be connected to 8 remote I/O stations, and 8 remote equipment station or intelligent equipment station.
Can be connected to FX3GA, FX3GE, FX3GC, FX3U and FX3UC of the host FR-A840-00930-2-60 Manual .
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 2.2KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) MITSUBISHI FR-A840-00930-2-60 Instruction manual MITSUBISHI FR-A840-00930-2-60 Instruction manual.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical MITSUBISHI FR-A840-00930-2-60 Instruction manual.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 1.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
BBasically can not be used FR-A840-00930-2-60 DETAILED. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-A840-00930-2-60 Manual .
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.