LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> L02CPU-CM Manual MITSUBISHI PLC L02CPU-CM Structured Text Programming Manual

L02CPU-CM Manual MITSUBISHI PLC L02CPU-CM Structured Text Programming Manual

Product model: L02CPU-CM
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
File size: 4.20MB
Thermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode MITSUBISHI PLC Programming Manual.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time L02CPU-CM To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost MITSUBISHI PLC Programming Manual.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs MITSUBISHI PLC Programming Manual.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling L02CPU-CM Programming Manual.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling) L02CPU-CM Programming Manual.
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control). Maximum transmission speed: 115.2kbps.
DC5V internal consumption current: 0.02A.
GOT connection.
MELSOFT connection.
Communication protocol support function serial communication function L02CPU-CM Programming Manual. SSCNET III /H remote station.
Transmission speed: 150Mbps.
End cap.
Play the role of SSCNET III /H remote station
SSCNET III /H host module is the MELSEC-L series of input and output modules and intelligent function modules connected to the SSCNET III /H moodule L02CPU-CM Manual.
Can be used as a remote station of motion controller,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
In addition, the module can be useed for the input and output of the motion controller by the circulating transmission, and the module of the SSCNET III /H host module can be installed MITSUBISHI PLC Programming Manual.
Related products
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro