LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> L02CPU-P Manual MITSUBISHI L02CPU-P Common Instructions Programming Manual

L02CPU-P Manual MITSUBISHI L02CPU-P Common Instructions Programming Manual

Product model: L02CPU-P
Name: PLC
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
File size: 19.95MB
Number of input channels: 8ch.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni120, Ni100, Cu100, Cu50.
Conversion speed: 40ms/ch.
Resolution: 0.1.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm MITSUBISHI L02CPU-P Programming Manual.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm L02CPU-P
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement MITSUBISHI L02CPU-P Programming Manual.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output MITSUBISHI L02CPU-P Programming Manual. Open collector output.
Axis of control: 4.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom L02CPU-P Manual.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same timee L02CPU-P Manual.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format.
Related products
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02CPU-CM
MITSUBISHI cpu module L02CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type. Prog