MITSUBISHI A0J2CPUR23 Manual A0J2CPUR23 Programming Manual

Product model: A0J2CPUR23
Name: PLC
Brand: MITSUBISHI
Sort: Programming Manual
File language: English
File size: 3.56MB
Ethernet network module 10BASE-T/10BASE5
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system A0J2CPUR23 Programming Manual.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved A0J2CPUR23 Programming Manual A0J2CPUR23
Q series PLC in the use of CC-Link function better,
And easier to use. Cable length 0.6m; used in A6TE2-16SRN.SI-200/250 fiber optic cable.
Double loop.
MELSECNET (II) (Master / local station).
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc A0J2CPUR23 Programming Manual. .
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps.
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram.
So far the system''s hardware electrical circuit has been determined. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points A0J2CPUR23 Manual.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type).
Using industry standard E-CONN type A0J2CPUR23 Manual.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.
Related products
MITSUBISHI
CPU unit
A0J2CPUP23
MITSUBISHI CPU unit A0J2CPUP23
Input and output points: 480 points. Program
MITSUBISHI
CPU unit
A0J2CPU
MITSUBISHI CPU unit A0J2CPU
Input and output points: 480 points. Program
MITSUBISHI
CPU unit
A0J2CPUR23
MITSUBISHI CPU unit A0J2CPUR23
Input and output points: 480 points. Program
MITSUBISHI
CPU unit
A0J2CPU-DC24-S2
MITSUBISHI CPU unit A0J2CPU-DC24-S2
Input and output points: 480 points. Program