MITSUBISHI A1S62TCTT-S2 Manual A1S62TCTT-S2 User's Manual

Product model: A1S62TCTT-S2
Name: Heating-Cooling Temperature Control Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.21MB
Output points: 64 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
32 points / a common end.
40 pin connector.
With circuit breaker protection function.
With the surge absorber.
Each scanning process. Focus on the input signal sampling A1S62TCTT-S2 User's Manual. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A1S62TCTT-S2
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program A1S62TCTT-S2 User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive A1S62TCTT-S2 User's Manual.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Analog RGB input system.
Applicable model: A985GOT-V. Cable 1.2m for the expansion of the floor, the expansion of a floor for every 1 units.Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measuure of how much the user application can store the number of indicators A1S62TCTT-S2 Manual .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words A1S62TCTT-S2 Manual . Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Temperature control module
A1S62TCRTBW-S2
MITSUBISHI Temperature control module A1S62TCRTBW-S2
Numer of channels: 2 channels. Sensing metho
MITSUBISHI
Temperature control module
A1S62TCTTBW-S2
MITSUBISHI Temperature control module A1S62TCTTBW-S2
Numer of channels: 2 channels. Sensing metho
MITSUBISHI
Temperature control module
A1S62TCRT-S2
MITSUBISHI Temperature control module A1S62TCRT-S2
Numer of channels: 2 channels. Sensing metho
MITSUBISHI
Temperature control module
A1S62TCTT-S2
MITSUBISHI Temperature control module A1S62TCTT-S2
Numer of channels: 2 channels. Sensing metho