Product model: A1S64TCTT-S1
Name: Temperature Control Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 2.69MB
Input type: DC input, negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, source.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 A1S64TCTT-S1 User's Manual. 1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type) A1S64TCTT-S1
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Applicable model: A956WGOT.Output points: 16 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink) A1S64TCTT-S1 User's Manual.
Response time: 2ms.
8 points / a common end.
20 point terminal station.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A1S64TCTT-S1 User's Manual.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control reqquirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A1S64TCTT-S1 Manual .
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A1S64TCTT-S1 Manual .
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Temperature control module
A1S64TCRTBW-S1
MITSUBISHI Temperature control module A1S64TCRTBW-S1
Numer of channels: 4 channels Sensing method
MITSUBISHI
Temperature control module
A1S64TCTT-S1
MITSUBISHI Temperature control module A1S64TCTT-S1
Numer of channels: 4 channels. Sensing metho
MITSUBISHI
Temperature control module
A1S64TCRT-S1
MITSUBISHI Temperature control module A1S64TCRT-S1
Numer of channels: 4 channels. Sensing metho
MITSUBISHI
Temperature control module
A1S64TCTRT
MITSUBISHI Temperature control module A1S64TCTRT
The most appropriate temperature regulation c