Product model: A1SJ71LP21GE
Name: MELSECNET/10 Network System
Brand: MITSUBISHI
Sort: Reference Manual
File language: English
File size: 18.74MB
Category: slave station.
Transfer speed: 125kbps/250kbps/500kbps/1Mbps.
Transmission line form: bus system.
Total distance: 125kbps:1000m/250kbps:800m/500kbps:480m/1Mbps:240m.
The maximum connection units: 32.
Total points: input + output <=2048 point.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures A1SJ71LP21GE Reference Manual .
These procedures are relatively independent, generally in the basic completion of the program design and then add A1SJ71LP21GE
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. Output points: 64 points.
Voltage: DC12/24V A1SJ71LP21GE Reference Manual .
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
32 points / a common end.
40 pin connector.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A1SJ71LP21GE Reference Manual .
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control reqquirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A1SJ71LP21GE Manual .
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A1SJ71LP21GE Manual .
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Network module
A1SJ71QBR11
MITSUBISHI Network module A1SJ71QBR11
3C-2V/5C-2V coaxial cale etween the single
MITSUBISHI
Melsecnet interface module
A1SJ71AP21-S3
MITSUBISHI Melsecnet interface module A1SJ71AP21-S3
PLC station distance: 2Km. Cale type: GI-50/
MITSUBISHI
Network module
A1SJ71QLP21
MITSUBISHI Network module A1SJ71QLP21
SI/QSI/H-PCF/ wide H-PCF optical cale doule