Product model: A2ASCPU-S60
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
File size: 3.29MB
AnS, QnAS bus connection, the reader to write program 1 channel connection.Input type: AC.
Input points: 16 points.
Input voltage: AC200-240V.
Input current: 11mA.
Connection mode: terminal row.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations A2ASCPU-S60 Programming Manual A2ASCPU-S60
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC A2ASCPU-S60 Programming Manual .
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram A2ASCPU-S60 Programming Manual . Its characteristics are basically consistent with the ladder diagram language. DC input points: 8 points.
Input voltage and current: 7mA, DC24V.
Response time: 10ms.
8 point /1 a public side.
Positive / negative sharing.
Output points: 8 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Response time: 12ms.
8 point /1 a public side.
Output form: relay output.
34 point terminal station.
Number of stations: 2 stops.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A2ASCPU-S60 Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness A2ASCPU-S60 Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
CPU unit
A2ASCPU-S30
MITSUBISHI CPU unit A2ASCPU-S30
I/O points: 1024. Processing speed: sec/ 0.15
MITSUBISHI
CPU unit
A2ASCPU-S1
MITSUBISHI CPU unit A2ASCPU-S1
I/O points: 512. Processing speed: sec/ 0.2u
MITSUBISHI
CPU unit
A2ASCPU
MITSUBISHI CPU unit A2ASCPU
I/O points: 512. Processing speed: sec/ 0.2u