LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A2SCPU Manual A2SCPU Fundamentals Programming Manual

MITSUBISHI A2SCPU Manual A2SCPU Fundamentals Programming Manual

Product model: A2SCPU
Name: PLC
Brand: MITSUBISHI
Sort: Fundamentals Programming Manual
File language: English
File size: 8.33MB
Long distance bus connection for QCPU.
Applicable models: GT16, GT15, GT11, GT27, GT25. Input points: 32 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Output points: 24 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0 A2SCPU Programming Manual. 5Hz+1ms.
Output type: bidirectional thyristor output.
36 point terminal station A2SCPU
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A2SCPU Programming Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A2SCPU Programming Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Series Name: A956GOT.
Size: 6 inches.
Resolution: 320 * 240.
Display device: STN color display.
Display color: 8 color.
Power supply: DC24V.
Memory card: 1M.
The external model design model of creating the system function is mainly to consider the data structure, the overall structure and the process description of the software,
The interface design is usually only used as accessories, only on the user''s situation (including age, gender, mental status, education level, personality, ethnic background and etc.) to understand, to design an effective user interface;
According to the user model of the future system of the end user (for short),
In the end, it is consistent with the system image (external characteristic) of the system after the systeem is realized,
Users can be satisfied with the system and be able to use it effectively;
When the user model is established, the information given by the system should be considered,
System mapping must accurately reflect the syntax and semantic information of the system A2SCPU Manual A2SCPU Manual .
In short, only to understand the user, to understand the task in order to design a good man-machine interface.
Related products
MITSUBISHI
Motion CPU module
Q173HCPU
MITSUBISHI Motion CPU module Q173HCPU
Control axis: maximum 32 axes. Teaching opera
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Motion controller
Q172DSCPU
MITSUBISHI Motion controller Q172DSCPU
Control axis: up to 16 axes. Servo amplifier