MITSUBISHI A3ACPUP21-S1 Manual A3ACPUP21-S1 Common Instructions Programming Manual

Product model: A3ACPUP21-S1
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
File size: 3.29MB
Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 A3ACPUP21-S1 Programming Manual . 1A.
External connection: 3 line /2 line type A3ACPUP21-S1
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. 26 point line conversion adapter 1 line type 16 input CC-Link unit installation special connection conversion adapterNSD servo system A3ACPUP21-S1 Programming Manual .
A73CPU (P21/R21) -S3 dedicated.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load A3ACPUP21-S1 Programming Manual .
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined accordiing to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point A3ACPUP21-S1 Manual.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% A3ACPUP21-S1 Manual.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
CPU unit
A3ACPU
MITSUBISHI CPU unit A3ACPU
Input and output points: 2048 points. Input /
MITSUBISHI
CPU unit
A3ACPUR21
MITSUBISHI CPU unit A3ACPUR21
Input and output points: 2048 points. Input /
MITSUBISHI
CPU unit
A3ACPUP21
MITSUBISHI CPU unit A3ACPUP21
Input and output points: 2048 points. Input /
MITSUBISHI
CPU unit
A2NCPUP21-S1
MITSUBISHI CPU unit A2NCPUP21-S1
Input and output points: 1024 points. Input /