LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A953GOT-TBD-M3 Manual A953GOT-TBD-M3 Hardware User's Manual

MITSUBISHI A953GOT-TBD-M3 Manual A953GOT-TBD-M3 Hardware User's Manual

Product model: A953GOT-TBD-M3
Name: touch screen
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
File size: 0.85MB
Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive and negative sharing.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side A953GOT-TBD-M3 User's Manual.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A953GOT-TBD-M3 User's Manual A953GOT-TBD-M3
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A953GOT-TBD-M3 User's Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Input voltage: AC100-240V.
Rated output: DC5V, 3A and DC24V, 0.6A.
The power supply module is connected with the external power supplyy, and the DC5V is provided with the AnS programmable controller,
They are inserted in the slot of the special power supply component on the base board,
The output of the DC5V is powered by the power supply on the substrate to the component A953GOT-TBD-M3 Manual A953GOT-TBD-M3 Manual.
The input voltage of the component is related to the selected model.
A1S61PN/62PN has Deng generation A1S61P/A1S62P, A1S61PEU/A1S62PEU.
Related products
MITSUBISHI
6 inch man machine interface
A953GOT-LBD
MITSUBISHI 6 inch man machine interface A953GOT-LBD
Series Name: A953GOT. Size: 6 inches. Resolut
MITSUBISHI
6 inch man machine interface
A953GOT-TBD-M3
MITSUBISHI 6 inch man machine interface A953GOT-TBD-M3
Series Name: A953GOT. Size: 6 inches. Resolut
MITSUBISHI
6 inch man machine interface
A953GOT-LBD-M3
MITSUBISHI 6 inch man machine interface A953GOT-LBD-M3
Series Name: A953GOT. Size: 6 inches. Resolut
MITSUBISHI
6 inch man machine interface
A953GOT-SBD-M3
MITSUBISHI 6 inch man machine interface A953GOT-SBD-M3
Series Name: A953GOT. Size: 6 inches. Resolut