Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AD57-S1 Manual AD57-S1 User's Manual

MITSUBISHI AD57-S1 Manual AD57-S1 User's Manual

Product model: AD57-S1
Name: CRT/LCD Controller Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 1.73MB
Optional features of memory card (Q/QnA/A/FX compatible).
4MB extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT. Fast connector type.
Voltage input.
Number of channels: 8 channels.
Occupied the number of stations: Ver.1 mode occupied 3 stations, Ver.2 mode occupied 1 stations AD57-S1 User's Manual.
Station type: remote equipment station.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction AD57-S1
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection AD57-S1 User's Manual.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust AD57-S1 User's Manual.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be. Output points: 8 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 8A/1 common end.
Output response time: 12ms.
8 point /1 a public side.
Output form: relay output.
24 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC prograam simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program AD57-S1 Manual AD57-S1 Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
Input module
AX41-S1
MITSUBISHI Input module AX41-S1
Input points: 32 points. Voltage: DC12/24V. C
MITSUBISHI
Analog output module
A68DAI-S1
MITSUBISHI Analog output module A68DAI-S1
8 channels. Input: DC0 20mA. Output resolu
MITSUBISHI
Display module
AD57-S1
MITSUBISHI Display module AD57-S1
MITSUBISHI PLC program simulation deugging T