Product model: AJ72QBR15
Name: remote I/O module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.18MB
Enter points: 64 points.
Input voltage: DC7V above.
Input response time: 16ms.
16 pin connector.
Output points: 64 points.
Output response time: 16ms.
Output type: transistor output.
32 pin connector.
Dynamic input and output.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AJ72QBR15 User's Manual AJ72QBR15 User's Manual AJ72QBR15
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor AJ72QBR15 User's Manual.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Series Name: A956GOT.
Size: 6 inches.
Resolution: 320 * 240.
Display device: STN monochrome display.
Display color: monochrome (white and black).
Power supply: DC24V.
Memory card: 1M.
The external model design model of creating the system function is mainly to consider the data structure, the overall structure and the process description of the software,
The interface design is usually only used as accessories, only on the user''s situation (including age, gender, mental status, education level, personality, ethnic background and etc.) to understand, to design an effective user interface;
According to the user model of the future system of the end user (for short),
In the end, it is consistent with the system image (external characteristic) of the system after the system iis realized,
Users can be satisfied with the system and be able to use it effectively;
When the user model is established, the information given by the system should be considered,
System mapping must accurately reflect the syntax and semantic information of the system AJ72QBR15 Manual AJ72QBR15 Manual .
In short, only to understand the user, to understand the task in order to design a good man-machine interface.
Related products
MITSUBISHI
SI/QSI fiber optic cable module
AJ72QLP25
MITSUBISHI SI/QSI fiber optic cable module AJ72QLP25
SI/QSI/H-PCF/ wide range H-PCF fier optic ca
MITSUBISHI
JEMANET (OPCN-1) module
AJ72J95
MITSUBISHI JEMANET (OPCN-1) module AJ72J95
Category: slave station. Transfer speed: 125k
MITSUBISHI
Optical fiber cable module
AJ72LP25
MITSUBISHI Optical fiber cable module AJ72LP25
Remote I/O controller, optical fier. How to