Product model: AY40-UL
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.41MB
Analog channel: 8 channels.
Input / output (resolution): 0 ~ 4000.
Conversion speed: 100ms/8 channel.
Analog module installation.
Power supply: DC24V.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system AY40-UL User's Manual AY40-UL
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong AY40-UL User's Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness AY40-UL User's Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. CC-Link master / slave station.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or aaddress number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next rround of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work AY40-UL Manual AY40-UL Manual .
Related products
MITSUBISHI
Transistor output module
AY41P
MITSUBISHI Transistor output module AY41P
Output points: 32 points. Voltage: DC12/24V.
MITSUBISHI
Transistor output module
AY42-S4
MITSUBISHI Transistor output module AY42-S4
Output points: 64 points. Voltage: DC12/24V.
MITSUBISHI
Transistor output module
AY41
MITSUBISHI Transistor output module AY41
Output points: 32 points. Voltage: DC12/24V.
MITSUBISHI
Transistor output module
AY40A
MITSUBISHI Transistor output module AY40A
Output points: 16 points. Voltage: DC12/24V.