Product model: CL1X4-D1S2
Name: CC-Link/LT Remote I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.27MB
Output type: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc CL1X4-D1S2 . are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module CL1X4-D1S2
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. No introductionOutput type: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A CL1X4-D1S2 .
External connection: 1 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. No introductionInput type: DC input, positive common end CL1X4-D1S2 .
Input points: 16 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Voltage and current output module.
Number of channels: 2 channels.
Occupied station number: 16 point pattern occupies 4 stations.
Screw terminal table type.
Input output points can be saved by using different input and output points based on the final channel that allows the conversion.
Special flat cable directly mounted to the module. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA.
External connnection: 1 wire CL1X4-D1S2 User's Manual.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be reeplaced with a simple module CL1X4-D1S2 User's Manual.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space.
Related products
MITSUBISHI
Spring clip terminal type input module
CL2X8-D1S2
MITSUBISHI Spring clip terminal type input module CL2X8-D1S2
Input type: DC input, positive pulic end / n
MITSUBISHI
Spring clip terminal type input module
CL1X4-D1S2
MITSUBISHI Spring clip terminal type input module CL1X4-D1S2
Input type: DC input, positive pulic end / n
MITSUBISHI
Sensor connection type input module
CL1X4-D1C3
MITSUBISHI Sensor connection type input module CL1X4-D1C3
Input type: DC input, positive common end. In
MITSUBISHI
Screw terminal type input module
CL1X4-D1B2
MITSUBISHI Screw terminal type input module CL1X4-D1B2
Input type: DC input, positive pulic end / n