Product model: CL1Y4-T1C2
Name: CC-Link/LT Remote I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.21MB
Input type: DC input, positive common end.
Input points: 4 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting MITSUBISHI CL1Y4-T1C2 User's Manual.
3 wire sensor input. Output type: transistor output, source CL1Y4-T1C2
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector MITSUBISHI CL1Y4-T1C2 User's Manual.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Input type: DC input, positive common end.
Input points: 8 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type.
Minimum size of industry MITSUBISHI CL1Y4-T1C2 User's Manual.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Output type: transistor output, drain type.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. No introductionOutput type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 2 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Input type: DC input, positive public end / negative public end.
Input points: 2 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 2 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0 CL1Y4-T1C2 Manual. 1A.
External connection: 2 line /2 line type.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole CL1Y4-T1C2 Manual.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.
Related products
MITSUBISHI
Screw terminal type output module
CL1Y4-T1B2
MITSUBISHI Screw terminal type output module CL1Y4-T1B2
Output type: transistor output, drain type. O
MITSUBISHI
Sensor connection type output module
CL1Y4-T1C2
MITSUBISHI Sensor connection type output module CL1Y4-T1C2
Output type: transistor output, drain type. O
MITSUBISHI
Spring clip terminal type output module
CL1Y4-T1S2
MITSUBISHI Spring clip terminal type output module CL1Y4-T1S2
Output type: transistor output, drain type. O
MITSUBISHI
Screw terminal type output module
CL1Y4-R1B2
MITSUBISHI Screw terminal type output module CL1Y4-R1B2
Output type: relay output. Output points: 4 p