Memory format: EPROM.
Number of steps:
Can use up to 16000 steps.
Battery support: do not.
Method of writing and deleting: write and use ROM to write, use ultraviolet ray to delete. MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 500kw.
SLD converter rated current: 1094A F940GOT-SWD-E Manual .
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have
F940GOT-SWD-E
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time F940GOT-SWD-E Manual .
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop. Analog output expansion board (1 channel) F940GOT-SWD-E Manual .
Can be installed in FX1N, PLC FX1S, providing 1 channel analog input of the board.
Because it is embedded in the PLC installation, so do not need to install space.
Can easily control the speed of the inverter. MITSUBISHI inverter FR-D740 series MITSUBISHI touch screen Manual .
Voltage level: three phase 400V.
Frequency converter capacity: 7.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible MITSUBISHI touch screen Manual .
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used MITSUBISHI touch screen Manual . For a single phase motor with governor switch, the auxiliary winding willl be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced F940GOT-SWD-E Installation Manual.
The inverter power supply is usually 3, but the capacity for small, single-phhase power is also useful functioning aircraft F940GOT-SWD-E Manual . Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.