LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-A740-7.5K-CHT Manual FR-A740-7.5K-CHT PLC FUNCTION PROGRAMMING MANUAL

MITSUBISHI FR-A740-7.5K-CHT Manual FR-A740-7.5K-CHT PLC FUNCTION PROGRAMMING MANUAL

Product model: FR-A740-7.5K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: PLC FUNCTION PROGRAMMING MANUAL
File language: English
File size: 3.53MB
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output."MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 15KW.
The use of frequency converter motor is in order to speed, and reduce the starting current FR-A740-7.5K-CHT PLC FUNCTION PROGRAMMING MANUAL.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification FR-A740-7.5K-CHT
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter FR-A740-7.5K-CHT PLC FUNCTION PROGRAMMING MANUAL. "MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 75kw.
SLD converter rated current: 380A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight) FR-A740-7.5K-CHT PLC FUNCTION PROGRAMMING MANUAL.
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. Analog input: 2.
Analog output points: 1 points.
Weight: 0.1kg.
FX3 series can be connected to the 2 channel input (voltage: DC0~10V, or current DC4~20mA), as well as 1 channel output (DC0~10V, or current: DC4~20mA) of the adapter.
Each channel can be specified as a current input or voltage input.
Connecting FX3SA, FX3S, FX3GA, FX3G, and FX3U main body, the need to convert the adapter or function expansion board FR-A740-7.5K-CHT Manual. Power: 15kw.
Voltage: 200V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connectedd without built-in brake transistor inverter FR-A740-7.5K-CHT Manual.
Three types of discharge resistors are available.
Please select according to the required braking torque.
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-400K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-400K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-160K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-160K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-45K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-45K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-7.5K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-7.5K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l