LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-A840-04320-2-60 Instruction manual FR-A840-04320-2-60 DETAILED Manual

MITSUBISHI FR-A840-04320-2-60 Instruction manual FR-A840-04320-2-60 DETAILED Manual

Product model: FR-A840-04320-2-60
Name: INVERTER
Brand: MITSUBISHI
Sort: DETAILED Instruction manual
File language: English
File size: 21.72MB
MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 75kw.
SLD converter rated current: 180A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup FR-A840-04320-2-60 Instruction manual FR-A840-04320-2-60
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor FR-A840-04320-2-60 Instruction manual.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FR-A840-04320-2-60 Instruction manual. MITSUBISHI inverter FR-D720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 0.1KW.
Vector control variable frequency speed control is the practice of the asynchronous motor in the three-phase coordinate system of the stator current Ia, Ib, Ic, through the three-phase to two-phase transformation,
The alternating current of Ia1Ib1 is equivalent to a two phase stationary coordinate system, and then is rotated by the rotor field oriented,
Equivalent to the DC current Im1, It1 (Im1 equivalent to DC motor excitation current in synchronous rotating coordinate system;
It1 equal to the armature current proportional to the torque, and then imitate the DC motor control method, to obtain the DC motor control,
The control of asynchronous motor is realized through the corresponding inverse coordinate transformation. Input and output points: 20 points.
Power supply: AC100-240V.
Input points: 12 points.
Output points: 8 points.
Output form: transistor output (source).
Power consumption: 20W.
Weight: 0.4KG.
Outline dimension: 75x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features.
Special adaptor and function expansion board can be installed and used FX3 series.
High speed operation.
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic modeel on the basis of the basic performance of the FX1S increased the expansion of the new models FR-A840-04320-2-60 Manual .
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so onn FR-A840-04320-2-60 Manual .
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on.