Power: 30kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost FR-E540-0.75K-CH TECHNICAL MANUAL.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving
FR-E540-0.75K-CH Series Name: F940WGOT.
System screen display language: english.
Display: 6.7 inch widescreen display.
Display color: 256 color.
Display device: LCD TFF.
Resolution: 480 * 234.
Installation type: panel mounting.
The built-in communication port: RS-422 (1ch) /RS-232C (2ch) FR-E540-0.75K-CH TECHNICAL MANUAL.
Power supply voltage: DC24V.
GOT-F900 series can be easily applied to a variety of different applications.
3 built-in communication channels.
3 standard communication ports are provided for the same PC (COM2:RS-232C) or a PLC (COM1:RS-232C and COM0:RS-422) communication.
Flexible layout.
F940WGOT can be installed in a vertical or horizontal direction.
The direction of the screen can be directed by programming software FR-E540-0.75K-CH TECHNICAL MANUAL.
Screen area.
Through the split screen configuration, you can reduce the operating time.
The image can be divided into two or three parts to display.
According to the user''s application example, the menu screen or the operation of the button sometimes on the screen will often be used to.
As a result, it is very time-consuming and inefficient to make a similar picture every time. Output points: 16 points.
Output form: transistor.
Connected programmable logic controller: FX1NC, FX2NC, FX3UC.
Weight: 0.15KG.
FX2NC expansion module can be directly connected to the FX1NC, FX2NC, PLC FX3UC on the expansion of the input and output.
Do not need to connect the cable and so on, therefore can carry on the compact expansion. Power: 3.7kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to rreach 300 degrees C or higher, it is necessary to take protective measures and cooling FR-E540-0.75K-CH Manual.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between thhe short circuit chip, in addition to connecting the DC reactor FR-E540-0.75K-CH Manual.
The installation of thermal relay, to avoid overheating and burn the braking resistor.