Power: 75kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose FR-F540-0.75K to 55K(-EC) Manual. ) MITSUBISHI inverter series: FR-F840
FR-F540-0.75K to 55K(-EC)
Voltage level: three phase 400V.
Power: 75kw.
SLD converter rated current: 180A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup FR-F540-0.75K to 55K(-EC) Manual.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor FR-F540-0.75K to 55K(-EC) Manual.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor) MITSUBISHI TRANSISTORIZED INVERTER Manual.
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving MITSUBISHI TRANSISTORIZED INVERTER Manual. Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: relay.
Power consumption: 25W.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Note recording function, Component annotation can be recorded in the program register MITSUBISHI TRANSISTORIZED INVERTER Manual.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eightt digit password to protect your program FR-F540-0.75K to 55K(-EC) INSTRUCTION MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FR-F540-0.75K to 55K(-EC) Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).