Power: 1.5kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor FR-F740P-560K-CHT Instruction manual.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table
FR-F740P-560K-CHT
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor FR-F740P-560K-CHT Instruction manual.
The installation of thermal relay, to avoid overheating and burn the braking resistor. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 15KW.
FR-A700 converter products are suitable for all kinds of high load requirements of the equipment.
Such as lifting, lift, printing and dyeing, printing and dyeing, material coiling and other general occasions FR-F740P-560K-CHT Instruction manual.
High level driving performance.
Unique sensorless vector control mode,
A wide variety of mechanical equipment can be operated at high precision in the super low speed region without the need of the encoder.
With torque control mode,
And in the speed control mode can use the torque limit function.
With vector control function (with encoder),
Frequency converter can achieve position control and fast response, high precision speed control (zero speed control, servo lock, etc.) and torque control. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 11kw.
SLD converter rated current: 25.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
GGive full play to the performance of the motor FR-F740P-560K-CHT Manual .
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FR-F740P-560K-CHT Manual .