LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-V540-11K-CH BASIC INSTRUCTION MANUAL

MITSUBISHI FR-V540-11K-CH BASIC INSTRUCTION MANUAL

Product model: FR-V540-11K-CH
Name: VECTOR INVERTER
Brand: MITSUBISHI
Sort: BASIC INSTRUCTION MANUAL
File language: English
File size: 4.44MB
MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 45KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment FR-V540-11K-CH BASIC.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit FR-V540-11K-CH
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on FR-V540-11K-CH BASIC. Can be used as a screw relay terminal.Max input / output points: 14 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 6 points.
Output type: Transistor (source).
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
All equipment is digital input and output point FR-V540-11K-CH BASIC.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 7.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used inn the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-V540-11K-CH INSTRUCTION MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-V540-11K-CH INSTRUCTION MANUAL. "
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-11K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-11K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-F740P-11K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-11K-CHT
"MITSUBISHI inverter FR-F740P series. Voltage
MITSUBISHI
3 phase 400V converter
FR-L740-11K-CHT
MITSUBISHI 3 phase 400V converter FR-L740-11K-CHT
MITSUBISHI inverter FR-L740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-F740-11K-CHT
MITSUBISHI 3 phase 400V converter FR-F740-11K-CHT
"MITSUBISHI inverter FR-F740 series. Voltage