LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FX-16EYS-ES-TB/UL Manual FX-16EYS-ES-TB/UL USER'S GUIDE

MITSUBISHI FX-16EYS-ES-TB/UL Manual FX-16EYS-ES-TB/UL USER'S GUIDE

Product model: FX-16EYS-ES-TB/UL
Name: INPUT AND OUTPUT TERMINAL BLOCKS
Brand: MITSUBISHI
Sort: USER'S GUIDE
File language: English
File size: 0.21MB
Max input / output points: 40 points.
Power supply voltage: DC24V.
Input points: 24 points.
Output points: 16 points.
Output type: transistor.
Power consumption (W): 32.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x75.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board FX-16EYS-ES-TB/UL USER'S GUIDE.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect FX-16EYS-ES-TB/UL
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control FX-16EYS-ES-TB/UL USER'S GUIDE. Input points: 32 points.
Output points: 32 points.
Output form: transistor.
Connected programmable logic controller: FX1NC, FX2NC, FX3UC.
FX2NC expansion module can be directly connected to the FX1NC, FX2NC, PLC FX3UC on the expansion of the input and output.
Do not need to connect the cable and so on, therefore can carry on the compact expansion FX-16EYS-ES-TB/UL USER'S GUIDE. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Max input / output points: 10 points.
Power supply voltage: 24VDC.
Input points: 6 points.
Output points: 4 points.
Output type: Transistor (source).
Power consumption (W): 6.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainlly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX-16EYS-ES-TB/UL Manual.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX-16EYS-ES-TB/UL Manual. "
Related products
MITSUBISHI
Terminal module
FX-16EYS-TB
MITSUBISHI Terminal module FX-16EYS-TB
Output points: 16 points. SCR output type.
MITSUBISHI
Output expansion module
FX-16EYR-ES-TB/UL
MITSUBISHI Output expansion module FX-16EYR-ES-TB/UL
Output: 16 points. Function: relay output. Co
MITSUBISHI
Output expansion module
FX-16EYT-ES-TB/UL
MITSUBISHI Output expansion module FX-16EYT-ES-TB/UL
Output: 16 points. Function: transistor outpu
MITSUBISHI
Output expansion module
FX-16EYS-ES-TB/UL
MITSUBISHI Output expansion module FX-16EYS-ES-TB/UL
Output: 16 points. Function: idirectional th