Product model: FX-232ADP
Name: COMMUNICATION ADAPTER
Brand: MITSUBISHI
Sort: USER'S GUIDE
File language: English
File size: 0.31MB
Max input / output points: 64 points.
Power supply voltage: 24VDC.
Input points: 32 points.
Output points: 32 points.
Output type: relay.
Power consumption: 35W.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation FX-232ADP Manual FX-232ADP
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FX-232ADP Manual.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 450kw.
SLD converter rated current: 962A FX-232ADP Manual.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON MITSUBISHI COMMUNICATION ADAPTER Manual.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time MITSUBISHI COMMUNICATION ADAPTER Manual.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation MITSUBISHI COMMUNICATION ADAPTER Manual.
Can reduce the power consumption in the stop. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 0.75KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used FX-232ADP USER'S GUIDE. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FX-232ADP Manual.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
Related products
MITSUBISHI
FX-30 connect PLC cable
FX-20P-CAB0
MITSUBISHI FX-30 connect PLC cable FX-20P-CAB0
Length: 1.5m. Specification: FX round connect
MITSUBISHI
Modular
FX3U-232ADP-MP
MITSUBISHI Modular FX3U-232ADP-MP
Applicale models: FX2NC-20GM. The contents o
MITSUBISHI
FX-30 connect PLC cable
FX-20CP-CADP
MITSUBISHI FX-30 connect PLC cable FX-20CP-CADP
Length: 0.3m. Specification: FX round connect