Product model: FX3U-32BL
Name: Battery
Brand: MITSUBISHI
Sort: Hardware Manual
File language: English
File size: 0.03MB
Input and output points: 60 points.
Power supply: DC24V.
Input points: 36 points.
Output points: 24 points.
Output form: transistor output (drain).
Power consumption: 29W.
Weight: 0.85KG.
Outline dimension: 175x90x86mm.
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series FX3U-32BL Hardware Manual.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application FX3U-32BL
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
High speed operation FX3U-32BL Hardware Manual.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.
Third generation standard model.
Easy to use integrated models and flexible scalability.
Condensed convenience of using the usual FX3 series.
Its high price by the most suitable for small scale control FX3U-32BL Hardware Manual. Output: 16 points.
Function: bidirectional thyristor output models.
Corresponding models: FX3GA, FX3G, FX3GE, FX3GC, FX3U, FX3UC.
Can carry on the FX3GC, the FX3UC basic unit and the expansion module or the localization module the connector and the terminal station transformation,
Save the time of the input and output connection, realize the labor saving.
The use of built-in input and output components models,
Can receive AC100V input, or through the relay or the transistor to drive large capacity load. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 15KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3U-32BL Manual.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX3U-32BL Manual. "
Related products
MITSUBISHI
PLC
FX3UC-96MT/DSS
MITSUBISHI PLC FX3UC-96MT/DSS
Input and output points: 96 points. Input poi
MITSUBISHI
RS-232 communication
FX3U-232ADP-MB
MITSUBISHI RS-232 communication FX3U-232ADP-MB
RS-232 communication. Special communication a
MITSUBISHI
PLC
FX3U-32MT/DS
MITSUBISHI PLC FX3U-32MT/DS
Max input / output points: 32 points. Power s
MITSUBISHI
PLC
FX3U-16MT/ES-A
MITSUBISHI PLC FX3U-16MT/ES-A
Max input / output points: 16 points. Supply