MITSUBISHI L02CPU Bulit-in I/O Function User's Manual

Product model: L02CPU
Name: CPU Module
Brand: MITSUBISHI
Sort: Bulit-in I/O Function User's Manual
File language: English
File size: 6.47MB
Temperature measurement resistor input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode L02CPU Bulit-in I/O Function.
Temperature regulation mode.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function L02CPU
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
Can make multi loop to reach the target value (SV) of the same time L02CPU Bulit-in I/O Function.
By setting the simultaneous heating of the channel group, up to 2 groups of units, respectively, at the same time warming.
It is very effective to use the control object that does not want to heat up to the time of arrival error.
Applicable to a variety of systems.
Sampling period switching function.
Sampling period can be selected from 250ms/4ch and 500ms/4ch L02CPU Bulit-in I/O Function.
Equipped with temperature input mode.
The temperature control module can be used as a temperature input module.
By setting the switch, you can easily change the input mode. AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, the local powwer supply can be connected with the 4 wire type mixed use L02CPU User's Manual.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power suupply L02CPU User's Manual.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load.
Related products
MITSUBISHI
CPU component
A2SHCPU
MITSUBISHI CPU component A2SHCPU
I/O control method: refresh mode or direct mo
MITSUBISHI
CPU unit
A2NCPUR21-S1
MITSUBISHI CPU unit A2NCPUR21-S1
Input and output points: 1024 points. Input /
MITSUBISHI
General purpose CPU
Q00UJCPU
MITSUBISHI General purpose CPU Q00UJCPU
Input / output points: 256 points. Numer of