LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L02CPU Manual L02CPU Design, Maintenance and Inspection User's Manual

MITSUBISHI L02CPU Manual L02CPU Design, Maintenance and Inspection User's Manual

Product model: L02CPU
Name: CPU Module
Brand: MITSUBISHI
Sort: Design, Maintenance and Inspection User's Manual
File language: English
File size: 14.84MB
Open collector output.
Axis of control: 4.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft L02CPU User's Manual.
Synchronous control of the axis and the positioning of the axis can coexist L02CPU
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control L02CPU User's Manual.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created L02CPU User's Manual.
Can import and export the cam data in CSV format. DC input.
Number of input channels: 2Ch.
DC5/12/24V input.
Maximum count rate: pulse/s 200k.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision contrrol L02CPU Manual.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized L02CPU Manual.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized.
Related products
MITSUBISHI
A bus connecting cable
A8GT-C12NB
MITSUBISHI A bus connecting cable A8GT-C12NB
Cale length: 1.2 meters. Long distance CPU e
MITSUBISHI
CPU unit
A1SJCPU
MITSUBISHI CPU unit A1SJCPU
Program memory capacity: 8k. Input / output p
MITSUBISHI
Motion controller
Q170MCPU
MITSUBISHI Motion controller Q170MCPU
Axis of control: 16. Compact Q170MCPU integra