"IE Field CC-Link master / local station
Transmission speed: 1Gbps.
Remote input / output: 16384 points.
Remote register: 8192 words.
Can be applied to the serial number of the top 5 for the "13012" and after the CPU module.
Simply set the parameters, you can easily start the network.
Simply use the Works2 GX, set the network parameters in the 1 master station, you can easily connect all the slave stations L02CPU-P Programming Manual
L02CPU-P
Also, when you need to change the system, you only need to change the parameters.
High degree of freedom network
Build star, linear, star and linear mixed model, and ring network,
Therefore, can freely set the scene equipment.
When you use HUB, you just need to connect the cable to the free port to build the network easily,
Additional equipment and re layout of the corresponding is also more simple L02CPU-P Programming Manual. "Number of input channels: 8ch.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni120, Ni100, Cu100, Cu50.
Conversion speed: 40ms/ch.
Resolution: 0.1.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm L02CPU-P Programming Manual.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. Input points: 32 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: 32 points).
External wiring connection mode: 40 pin connector.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
IIs an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L02CPU-P Manual L02CPU-P Manual.