Output points: 32 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector L06CPU-CM Programming Manual.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called
L06CPU-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol L06CPU-CM Programming Manual. Number of input channels: 8ch.
Input voltage: DC - 10 ~ 10V.
Conversion speed: 1ms/ch.
Resolution: 1/16000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup L06CPU-CM Programming Manual.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected. Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (source).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points).
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge prottection function, with 3000V photoelectric isolation L06CPU-CM Manual.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible L06CPU-CM Manual.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.