Input points: 16 points.
Input voltage and current: 8mA AC100-120V (AC100V; 60Hz) /7mA (AC100V; 50Hz).
Response time: 20ms.
16 points / a common end.
18 point spring clip connection terminal.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q00CPU Application
Q00CPU
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control Q00CPU Application.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users Q00CPU Application.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.The telephone line of the interface module is connected with the peripheral equipment.Input: 8 channels.
30kpps/10kpps/1kpps/100pps/50pps/10pps/1pps/0.1pps.
Counter input signal: DC5/12-24V.
The module is suitable for the meeasurement of the number of input pulses, such as speed, speed, instantaneous flow rate and so on,
As well as the quantity, the length, the cumulative flow and so on the measurement Q00CPU User's Manual.
Input pulse values are updated every 10ms.
Thhe number of pulses (sampling pulse number), which can be accumulated and processed by the moving average, is updated according to the counting period Q00CPU User's Manual.