3C-2V/5C-2V coaxial cable.
Single bus.
PLC to PLC network (control station / common station) / remote I/O net (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station Q00JCPU-S8 Manual
Q00JCPU-S8
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network Q00JCPU-S8 Manual.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Connect to read and write 2Ch.
ID system interface module.
ID controller M-688-001/002 BIS can be installed directly to the Q series of substrates,
Control module for reading and writing ID tag data through a programmable logic controller Q00JCPU-S8 Manual.
The ladder diagram of M-688-002 BIS is compatible with QD35ID1/2.
2 antennas can be connected, and the parallel processing of the 2 channels can be simultaneously carried out.
Can use all ID tags in the M BIS series MITSUBISHI CPU Manual.
ID series /BIS system is an industrial automation ID system which can use the electromagnetic combination method to read and write data MITSUBISHI CPU Manual.
ID tag has a variety of sizes and storage capacity.Axis of control: 16.
Compact Q170MCPU integrated power supply module, PLC and motion controller,
And built in the packaging equipment used in the incremental synchronous encoder signal and signal detection signal required for the interface,
Do not need to add the appropriate module MITSUBISHI CPU Manual.
Reduce the design cost of the system expansion!
Although the structure is compact, but as a motor controller based on the iQ platform of MITSUBISHI motor,
Q170MCPU as an independent motion controller, also has high performance and easy to use.Input: 4 channels.
Platinum resistance (Pt10; JPt100).
Conversion speed: 40ms/1.
Channel 18 point terminal.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100).
Shedding detection function.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent thee loss of the program and the parameters due to forgetting to replace the battery Q00JCPU-S8 Strctured Programming Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and otther planned downtime,
The data is lost due to battery depletion Q00JCPU-S8 Manual.
The next time the power is turned on, the backup data will be automatically restored.