LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q02CPU Programming Manual Q02CPU SFC Manual

MITSUBISHI Q02CPU Programming Manual Q02CPU SFC Manual

Product model: Q02CPU
Name: CPU
Brand: MITSUBISHI
Sort: SFC Programming Manual
File language: English
File size: 2.11MB
Battery replacement.
Initial voltage 3.0V.
Replacement of large capacity battery module without cable.
Current capacity: 18000mAh.
Service life: 5 years.
Outline dimension: 98*55.2*87mm.Control axis: maximum 32 axes.
Teaching running function: there (when using SV13).
To stop the speed control function at the specified location Q02CPU Programming Manual .
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,
Can be set in advance to stop the location Q02CPU
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / deceleration time.
Phase compensation function.
The mixed function of virtual mode and real mode Q02CPU Programming Manual .
Smooth clutch linear acceleration / deceleration function.4 axis, differential drive output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 4Mpps.
40 pin connector.
Differential output.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing Q02CPU Programming Manual .
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time tto manage the backup data, but also can shorten the recovery time of the system shutdown Q02CPU Manual. Set high performance CNC and high speed programmable controller as a whole.
Integrating the high performance CNC with the high speed programmablee controller helps to shorten the overall cycle time Q02CPU Manual.
Support a rich variety of FA modules, can be flexible to meet the needs of different applications.
Related products
MITSUBISHI
Movement CPU
R32MTCPU
MITSUBISHI Movement CPU R32MTCPU
"Axis of control: 32. Program language: motio
MITSUBISHI
CPU unit
A1FXCPU
MITSUBISHI CPU unit A1FXCPU
Input and output points: 224 points. Input /
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o