LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q03UDVCPU Manual Q03UDVCPU Fundamentals Strctured Programming Manual

MITSUBISHI Q03UDVCPU Manual Q03UDVCPU Fundamentals Strctured Programming Manual

Product model: Q03UDVCPU
Name: CPU
Brand: MITSUBISHI
Sort: Fundamentals Strctured Programming Manual
File language: English
File size: 1.73MB
GI-62.5/125 optical cable.
Double ring.
PLC to PLC network (control station / common station) / remote I/O net (remote master station).Resolution 262144PLS/res.
Allow speed 3600r/min.
Allowable load of shaft: the maximum of 19.6N, the maximum axial direction is 9.8N.
Convenient processing of large capacity data Q03UDVCPU Strctured Programming Manual.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming Q03UDVCPU
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area Q03UDVCPU Strctured Programming Manual.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved Q03UDVCPU Strctured Programming Manual.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.Output points: 16 points.
Output voltage and current: 24V/AC240V 2A/1; DC point; 8A/1 common end.
Response time: 12ms.
16 points / a common end.
18 point spring clip connection terminal.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Workks2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q03UDVCPU Manual. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q03UDVCPU Manual.
Related products
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Numer of
MITSUBISHI
CPU unit
A3VCPU
MITSUBISHI CPU unit A3VCPU
Multiple CPU units for A3VTS multiplex system
MITSUBISHI
General high speed CPU
Q04UDVCPU
MITSUBISHI General high speed CPU Q04UDVCPU
Input / output points: 4096 points. Input / o