LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q06CCPU-V-B Programming Manual PLC MELSAP-L Manual

MITSUBISHI Q06CCPU-V-B Programming Manual PLC MELSAP-L Manual

Product model: Q06CCPU-V-B
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
File size: 3.16MB
High performance type CPU, process CPU, memory card protection cover for redundant CPU.
Q3MEM-4MBS-SET bundled products.GI-50/125 optical cable.
Double ring.
Remote I/O net (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station Q06CCPU-V-B Manual Q06CCPU-V-B
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network Q06CCPU-V-B Manual .
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0 Q06CCPU-V-B Manual . 5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling MITSUBISHI PLC Manual .
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode MITSUBISHI PLC Manual .
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost MITSUBISHI PLC Manual .
Heating function at the samee time Q06CCPU-V-B Programming Manual.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q06CCPU-V-B Manual .
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
C language CPU
Q06CCPU-V-H01
MITSUBISHI C language CPU Q06CCPU-V-H01
Input / output points: 4096 points. You can u
MITSUBISHI
C language CPU
Q06CCPU-V
MITSUBISHI C language CPU Q06CCPU-V
Input / output points: 4096 points. You can u
MITSUBISHI
C language CPU
Q06CCPU-V-B
MITSUBISHI C language CPU Q06CCPU-V-B
Input / output points: 4096 points. You can u