PCI bus.
Support Japanese, English OS.
GI optical cable.
Dual loop controller network (control station / common station).
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q06PHCPU Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of
Q06PHCPU
Even if the information reaches saturation, it will not affect the link scan time.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability Q06PHCPU Manual.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.Battery replacement.
Initial voltage 3.0V.
Service life: 5 years.8 axes, open collector output type.
Control unit: pulse.
Location data: 10 data / axis Q06PHCPU Manual.
Maximum pulse output: 200Kpps.
40 pin connector.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing MITSUBISHI CPU Manual.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types MITSUBISHI CPU Manual.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps MITSUBISHI CPU Manual. )
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card. Q06PHCPU Strctured Programming Manual.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q06PHCPU Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.