Input points: 16 points.
Input voltage and current: 6mA DC5V.
Response time: 0/0.1/0.2/0.4/0.6/1ms.
8 point /1 a public side.
Common cathode.
18 point terminal station.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q12DCCPU-V Manual. And there is no need to select the cable, the straight line and the cross line can be used
Q12DCCPU-V
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location Q12DCCPU-V Manual.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control Q12DCCPU-V Manual.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password MITSUBISHI PLC Manual.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users MITSUBISHI PLC Manual.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.The input and output module installation number: 4.
Could extend the connection: not to extend the connection MITSUBISHI PLC Manual.
Application module: QS series module.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outsidee the standard control procedures Q12DCCPU-V User's Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q12DCCPU-V Manual. "