2 channel.
Differential input: 40kpps/400kpps/800kpps/2Mpps/4Mpps/8Mpps.
Count input signal: EIA standard RS-422-A (differential line driver).
DC input: 10kpps/100kpps/200kpps.
Count input signal: DC5/12/24V 7 ~ 10mA.
External output: DC24V.
Consistent output: Transistor (drain), DC12/24V, 0.1A/ point, 0 MITSUBISHI CPU Strctured Programming Manual. 8A/ common.
40 pin connector.
Multifunctional counting / timing module (QD65PD2)
Very precise positioning and tracking
Q12DCCPU-V
Maximum count rate of up to 8Mpps (differential input 4 phase 2 frequency multiplication), is 2 times in the past.
Multifunctional and convenient use!
Pulse measuring function... Measurement resolution of 100ns, can be performed with high precision pulse measurement.
PWM output function MITSUBISHI CPU Strctured Programming Manual. .. Configuration of the maximum 200 PWM kHz output function. Available 0.1 s single
Bit change duty cycle, to achieve ultra precise output control.
Cam switching function... The output of the 8 points, 16 step / output cam switch.
High precision timing control can be realized by cam switch.
Complete complex control using a consistent test!
Uniform output function... Can provide support for complex applications MITSUBISHI CPU Strctured Programming Manual.
According to the specific circumstances, choose to use the cam switch function or the same output function.SRAM memory card.
RAM capacity: 128KB. RS232 cable for connecting cables and 3M, CPU.Input: 4 channels Q12DCCPU-V Strctured Programming Manual.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function Q12DCCPU-V Strctured Programming Manual.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q12DCCPU-V Strctured Programming Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loopp can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q12DCCPU-V Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process MITSUBISHI CPU Strctured Programming Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.