Product model: Q13UDEHCPU
Name: CPU
Brand: MITSUBISHI
Sort: Fundamentals Strctured Programming Manual
File language: English
File size: 1.73MB
SRAM memory card.
RAM capacity: 64KB. Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA.
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode Q13UDEHCPU Fundamentals.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc Q13UDEHCPU.
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response Q13UDEHCPU Fundamentals.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integration time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station Q13UDEHCPU Fundamentals. Master station.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
QJ61CL12 can be used as the main station of CC-Link/LT.Upgraded version.
Control axis: maximum 8 axes.
Peripheral I/F: by CPU PLC.
Manual pulse generator operation function: can use 3 sets of manual pulse generator.
Synchrronous encoder operation function: can use 8 synchronous encoder Q13UDEHCPU Strctured Programming Manual.
CPU special high speed communication bus, each 0.88ms cycle can exchange 14K data word.
Exercise basic performance is about 2 times, sports SFCC processing time is reduced by about 1/4 Q13UDEHCPU Strctured Programming Manual.
PLC interrupt program to achieve high-speed synchronization between multiple CPU.
Motion specific instruction
Related products
MITSUBISHI
General high speed CPU
Q13UDVCPU
MITSUBISHI General high speed CPU Q13UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
With Ethernet CPU
Q26UDEHCPU
MITSUBISHI With Ethernet CPU Q26UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q50UDEHCPU
MITSUBISHI With Ethernet CPU Q50UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q20UDEHCPU
MITSUBISHI With Ethernet CPU Q20UDEHCPU
Input / output points: 4096 points. Numer of