1 axes, open collector output type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types Q13UDEHCPU Programming Manual.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control
Q13UDEHCPU
(the command pulse of the open collector positioning module is highest 200kpps.) Program capacity: 8K step.
Input / output points: 1024 points.
Number of input and output elements: 2048 Q13UDEHCPU Programming Manual.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users Q13UDEHCPU Programming Manual.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.Input: 4 channels.
Thermocouple (C1602~1995 JIS).
Micro voltage (-100mV~100mV).
Conversion speed: (sampling period x3) /1 channel.
18 point terminal station.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Thhrough regular backup, can be the latest parameters, procedures, etc Q13UDEHCPU Manual . to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q13UDEHCPU Manual .
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.