LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q172DCPU-S1 Programming Manual Q172DCPU-S1 MELSAP-L Manual

MITSUBISHI Q172DCPU-S1 Programming Manual Q172DCPU-S1 MELSAP-L Manual

Product model: Q172DCPU-S1
Name: CPU
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
File size: 1.76MB
Three-phase 3 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information Q172DCPU-S1 Programming Manual Q172DCPU-S1
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment Q172DCPU-S1 Programming Manual.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk Q172DCPU-S1 Programming Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.PCI bus.
Support Japanese, English OS.
3C-2V/5C-2V coaxial cable.
Single bus controller network (control station / common station).
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q172DCPU-S1 Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q172DCPU-S1 Manual.
Even if the information reaches saturation, it will not affect the link scan time.
Related products
MITSUBISHI
CPU unit
Q2ACPU-S1
MITSUBISHI CPU unit Q2ACPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
Servo external signal interface module
Q172DLX
MITSUBISHI Servo external signal interface module Q172DLX
Input points: servo external signal 32 points
MITSUBISHI
CPU unit
A2USHCPU-S1
MITSUBISHI CPU unit A2USHCPU-S1
I/O points: 1024. Processing speed: 0.09 sec/
MITSUBISHI
CPU unit
A2ACPU-S1
MITSUBISHI CPU unit A2ACPU-S1
Input and output points: 1024 points. Input /