Product model: Q173DSCPU
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
File size: 3.16MB
8 channels.
Thermocouple (B, R, S, K, E, J, T, N)
Shedding detection function.
Conversion speed: 640ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance Q173DSCPU MELSAP-L.
Products can choose multi-channel (8 channel) input type and channel isolation type Q173DSCPU
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion Q173DSCPU MELSAP-L.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card Q173DSCPU MELSAP-L.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. Positioning: 3 axis, built-in counter function, open collector output type.
Control unit: pulse.
Number of location data: 1/ axis.
Maximum output pulse: 100Kpps.
Counter: 3 channels.
100Kpps.
Counter input signal: DV5~24V.
40 pin connector.
Positioning control using encoder feedback, especially suitable for conveying system and processing machinery, etc..
In the 1 single module, the 3 axis positioning function and the 3 channel counter function are integrated.
Positioning module, high-speed counter module combined as a whole,
Can effectively use the board slot and save space. Input points: 32 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
32 points and 1 common ends.
Common anode.
Output points: 32 points.
Output voltage and current: DC12-24V; 0.1A/ point; 2A/ common.
Response time: 1ms.
1 point 32 public end, leakage type; 40 pin connector.
With thermal protection.
With short circuit protection.
With the surge absorber.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceiver time between the CPU module.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily displayed.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K wword,
And to achieve the extension to the file register to all regions of the file register Q173DSCPU Programming Manual.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured daata (array),
The speed has been improved Q173DSCPU Programming Manual.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
Related products
MITSUBISHI
Motion CPU module
Q173DCPU
MITSUBISHI Motion CPU module Q173DCPU
Control axis: maximum 32 axes. Manual pulse g
MITSUBISHI
Motion CPU module
Q173CPUN-T
MITSUBISHI Motion CPU module Q173CPUN-T
Control axis: maximum 32 axes. Teaching runni
MITSUBISHI
Motion CPU module
Q173HCPU
MITSUBISHI Motion CPU module Q173HCPU
Control axis: maximum 32 axes. Teaching opera
MITSUBISHI
Motion CPU module
Q173CPUN
MITSUBISHI Motion CPU module Q173CPUN
Control axis: maximum 32 axes. Compact size a