Product model: QD51
Name: Corresponding Intelligent Communication Module
Brand: MITSUBISHI
Sort: Command Programming Manual
File language: English
File size: 7.68MB
Control axis: maximum 8 axes.
Teaching operation function: No.
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,
Can be set in advance to stop the location.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / deceleration time QD51 Command QD51
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.High speed data communication module.
10BASE-T/100BASE-TX.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module QD51 Command.
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet.
Realize the previous communication method can not achieve the detailed control of data transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value QD51 Command. Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same timme QD51 Programming Manual.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process QD51 Programming Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
Open collector output (upgraded version)
QD75P1N
MITSUBISHI Open collector output (upgraded version) QD75P1N
1 axes, open collector output type. Control u
MITSUBISHI
High speed counting module
QD62-H02
MITSUBISHI High speed counting module QD62-H02
Input: 2 channels. 10kpps. Counter input sign
MITSUBISHI
Corresponding III SSCNET positioning module
QD74MH16
MITSUBISHI Corresponding III SSCNET positioning module QD74MH16
16 axes. Connect SSCNET III. Control unit: pu